Check the spectrum before you balance: an industrial fan case

A customer of ours in the USA took on a first-ever balancing job: a large industrial fan, with a complaint of strong vibration during run-up. Before any weights were installed, we asked to open the vibrometer mode of the Balanset-1A. The overall vibration level at operating speed was 2.51 and 3.10 mm/s against an allowable 4.5 mm/s (ISO 14694). By the numbers, the machine is in good condition.

Industrial fan with its drive motor on a common frame

Vibrometer mode: overall level 3.10 mm/s on the second channel, time signal and spectrum

The spectrum showed why it shakes anyway. Unbalance gives one tall peak in the spectrum, at the rotation frequency. Here the main peak was followed by a whole series of others, from 50 to 100 Hz. This is what a machine looks like when something in it is loose or worn.

Vibration spectrum: the main peak and a series of further peaks from 50 to 100 Hz

The plant manager confirmed it: the bearings of this fan had been due for replacement for a long time. Balancing was postponed until after the repair.

A short check in vibrometer mode before the work saves fiddling with weights that will change nothing.

One more detail from this job. The tachometer was first mounted in the inspection opening of the housing, next to the impeller. That is dangerous: it can be pulled into the impeller. We moved it to the shaft, between the bearing and the housing.

The first tachometer position: in the inspection opening of the housing, next to the impeller

Tachometer on a magnetic stand aimed at the shaft, vibration sensor at the bearing support

Reflective mark on the shaft between the bearing and the housing

Vibration sensors at the drive motor

More at vibromera.eu.

Top comments (0)