2.5 MW turbo generator rotor balanced in its own bearings

Trailokya Late and the specialists of ROTOMECH BALANCING (India) have balanced the rotor of a 2.5 MW alternator driven by a steam turbine. The work was done on site with the Balanset-1A, with the rotor in its own bearings, without removing it from the machine.

2.5 MW alternator driven by a steam turbine through a gearbox

Vibration before balancing: 8.6 mm/s and 3.6 mm/s in the X and Y directions.

Vibration after balancing: 0.4 mm/s and 0.2 mm/s.

End view of the alternator: bearing housing and the rotor behind it

The correction weights are shown in the photos: 430 g at 278° and 300 g at 12°, which is equivalent to a combined mass of 540 g at 315°.

Correction weight installed on the rotor: 430 g at 278°

Both correction weights and the equivalent combined mass: 540 g at 315°

The same team holds the record for the heaviest rotor balanced with a Balanset-1A that we know of: a sugar mill fiberizer rotor of 26,000 kg. Before that, the record belonged to my friend Ilya, who balanced a 25-tonne rotor running at 3000 rpm for a power plant.

Thanks to Trailokya Late for the photos and the data.